4.2 Unpacking and inspecon
• 1 x LiveCore™ unit
• 1 x Power supply cord
• 1 x Ethernet cross cable (for device control)
• 1 x Web-based Remote Control Soware included and hosted on the device
• 1 x Rack mount kit
• 1 x User manual (PDF version)*
• 1 x Quick start guide*
* User manual and Quick start guide are also available on www.analogway.com
Before racking and plugging any inputs and outputs, it is advised to power on the unit. Should you encounter
any issue, you must contact immediately your local distributor or dealer, or closest Analog Way technical
support oces (see chapter: 14. Contact informaon).
LiveCore™ unit can be used directly on a table; the unit is equipped with 4 handy an-
slip rubber feet.
LiveCore™ unit is compable with a 19” enclosure. Please follow the instrucons below to
install the device in a 19” rack.
a 4U LiveCore™ unit weighs 42.77LBS (19,4Kg) and 3U weighs 30.86LBS (14Kg). Please provide
appropriate support to the frame during installaon. First, place ears on each side of the device (ref: 180469)
Place the device in your rack. Aach the device to the rack by using 2 screws through the ears (screws not
included).
Addional support, such as the rear rack support or slide rails, is required. LiveCore™ unit is equipped with
threaded holes designed for compability with a rear rack mount such as ref. 180489. Use the holes in the
rear support arm to adjust the length of the rear rack support arm in order to reach the rear rack rail when
installed in the rack. Use four M4x10mm screws in the countersunk holes in the rear support bar on both
sides of the unit.
A lacing bar is provided with the rack mount kit (ref: 180489). Install it with the M4x10 screws according to
your cables posion.
Connect all of the cables to the device and aach them to the lacing bar with the help of e wraps.
- The openings in the front and rear panels of the device are for cooling. Air ows from front to back. Do not
cover these openings to avoid cung air circulaon.
- The maximum ambient operang temperature should not exceed 40°C (104°F).
- The rack and all mounted equipment in it must be reliably grounded according to naonal and/or local
electrical standards.
4.2
4.3
CAUTION!
Mounng using only the front rack ears is sucient for xed installaons. Addional support, such as the rear rack support or
slide rails, is required for mobile applicaons, and recommended for all.