STUDIO SCAN XTD 620 Chapter 10 : RS-232 PROGRAMMER'S GUIDE
PAGE 21
MISCELLANEOUS CONTROLS
c command controls actions from Front panel (DTC actions)
bit 7
(
128
)
bit 6
(
64
)
bit 5
(
32
)
bit 4
(
16
)
bit 3
(
8
)
bit 2
(
4
)
bit 1
(
2
)
bit 0
(
1
)
00 = Front panel (DTC) unlocked.
01 = DTC locked.
1x = DTC locked with help message.
1 = Following control message due to DTC action.
1 = Horizontal position control (Hpo) at Max value.
(generally less than 255)
1 = Vertical position control (Vpo) at Max value.
b command controls status from DTC or action to DTC
bit 7
(
128
)
bit 6
(
64
)
bit 5
(
32
)
bit 4
(
16
)
bit 3
(
8
)
bit 2
(
4
)
bit 1
(
2
)
bit 0
(
1
)
1 = POS/SIZE button in position POS
1 = Store the image setting
1 = Erase the previous image setting
1 = Freeze active
1 = Recall previous image POS / ZOOM setting
? command returns device type 1 = XTD820 type.
2 = XTD620 type.
M, L, r commands returns firmware versions.