Chapter 10 : RS-232 PROGRAMMER'S GUIDE STUDIO SCAN XTD 620
PAGE 20
GENLOCK CONTROLS
k command is used to read the Genlock status.
Value returned mean: 0 = No Genlock signal
1 = Genlock signal ON and OK
2 = Wrong Genlock signal
I command controls the sub carrier phase (Sc Ph) of the Genlock with 1024 levels from 0 to 1023.
i command controls the Horizontal Synchro phase (H Ph) of the Genlock with 256 levels from 0 to 255.
INPUT STATUS CONTROLS
This control family is read only. They can’t be preceded with value.
u command returns the UNIT value.
d command returns the DHI value.
The following formula allow to calculate the computer input line frequency (in kHz): UNIT VALUE
DHI VALUE
l command returns the GRT value.
The following formula allow to calculate the input frame frequency (in Hz) : Input Line Frequency (Hz)
GRT Value
t command returns Input signal status.
bit 7
(
128
)
bit 6
(
64
)
bit 5
(
32
)
bit 4
(
16
)
bit 3
(
8
)
bit 2
(
4
)
bit 1
(
2
)
bit 0
(
1
)
1 = Presence of Input signal.
0 = Negative H Sync Input.
1 = Positive H Sync Input.
0 = Negative V Sync Input.
1 = Positive V Sync Input.
xx0 = Separated H&V Sync.
x01 = Sync On Green (SOG).
011 = 1V Composite Sync.
111 = TTL Composite Sync.
1 = Non Interlaced Input signal.
1 = Input signal is Out of Range.