Chapter 10 : RS-232 PROGRAMMER'S GUIDE STUDIO SCAN XTD 620
PAGE 18
10-2. COMMANDS AND RESPONSES TABLE
The following table resumes commands which are recognized as valid and the responses that will be returned to the host
(on RS-232 port).
VALUE EXAMPLESASCII
COMMAND
RESPONSE
TO HOST
COMMAND
DESCRIPTION
MIN MAX COMMAND RESPONSE ACTION
EXPLANATION
Image commands
H Hpo Horizontal positioning 0 255 20H Hpo20 Set Hpos to 20
V Vpo Vertical positioning 0 255 V Vpo73 Read V position
W Hsz Horizontal width 0 255 W Hsz128 Read H width
S Vsz Vertical size 0 255 157S Vsz157 Set Vsize
h Hpn Horizontal panning 0 255 128h Hpn128 Set H panning
v Vpn Vertical panning 0 255 v Vpn102 Read V panning
w Hzm Horizontal zoom factor 0 255 100w Hzm100 Set H zoom
s Vzm Vertical zoom factor 0 255 150s Vzm150 Set V zoom
Output commands
* T TSO Output standard 0 63 T TSO33 Read Output standard
F FLK Filter Flicker level 0 7 4F FLK4 Set to level # 4
N BLV Black level 0 255 N BLV128 Read Black level
R REDLV Red level 0 255 106R REDLV106 Set Red level
G GRELV Green level 0 255 G GRELV128 Read Green level
B BLULV Blue level 0 255 B BLULV127 Read Blue level
Genlock controls
k GLK Genlock status 0 2 k GLK0 Read Genlock status
I SCPH Sub carrier phase setting 0 1023 522I SCPH522 Set SC Ph
i HPHI Horizontal Sync phase setting 0 255 138i HPHI138 Set H Ph
Input status (Read only)
d DHI Horizontal period of input
signal
0 65535 d DHI564 Read line frequency
l GRT Number of line per field 0 65535 l GRT525 Read line per field
* t TSY Sync type 0 255 t TSY113 Read Sync type
u UNIT Measures unity in kHz 0 65535 u UNIT17734 Read unity of measures
Miscellaneous
* c MISC Miscellaneous controls 0 31 c MISC0 Read controls
* b BP Front panel actions 0 31 8b BP8 Set Freeze mode
? DEV device type 0 2 ? DEV1 Read device type
M M_ "M" Firmware Version 0 65535 M M_13316 Read "M" Version
L L_ "L" Firmware Version 0 65535 L L_18915 Read "L" Version
r R_ "R" Firmware Version 0 65535 r R_57427 Read "R" Version
* See Chapter 10-4 COMMANDS DESCRIPTION
10-3. ERROR RESPONSES
When the STUDIO SCAN receives from the host an invalid command or value, it returns an error response:
E10 invalid command (See : "Command" Column)
E13 invalid value (See "Value" Column)