Analog-way PULSE LE - Ref. PLS200 Programmer's Guide Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
15
Group
Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SIG_VPOL sv sv Input V sync polarity Rd 0 1 0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_SYNC_TYPE sK sK Input sync type Rd 0 3 0
0 = Séparated Synchros H&V
1 = Composite TTL Synchro
2 = Composite Analog Synchro
3 = Synchro on Green (SOG)
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_FIELD sf sf Input frame frequency Rd 0 655350 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SIG_FREQ_LINE sl sl Input line frequency Rd 0 655350 Unit = 1/100Hz
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 51 52