Group Name Cmd
RespDescription
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
IN_SYNCHRONIZED iY iY VIS Synchronisation group Rd/Wr 0 3 0
0 = Does not belong to any VIS
Group
1 = Groupe VIS 1 group for
analog input
2 = Groupe VIS 2 group for
analog input
3 = Groupe VIS 3 group for
analog input
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_HDCP_ENABLE iH iH
Enable/disable the HDCP support of
a DVI input
Rd/Wr 0 1 1
10 = Input11
11 = Input12
IN_HDCP_CABLE_LEN iC iC Lenght of an DVI input cable Rd/Wr 0 2 0
0 = Less than 10 meter cable
length
1 = 5 to 20 meters cable length
2 = More than 15 meters cable
length
10 = Input11
11 = Input12
KEYING
IN_KEYING_TYPE KT KT Keying type Rd/Wr 0 4 0
0 = No keying
1 = Luma Key Keying
2 = ChromaKey Keying
3 = Luma Key Keying + DSK
4 = ChromaKey Keying + DSK
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_R_LEVEL KR KR Keying level (Red ) Rd/Wr 0 255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14