Analog-way Eikos - EKS500 Programmer's Guide Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 55
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
18
Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
42 = CPU 1366x768
SIG_FORMAT_LIST sL sL
Bit field of the fomats
compatible with the detected
format
Rd 0 255 0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
0 = Bits 0 to 7 Slice
1 = Bits 8 to 15
Slice
2 = Bits 16 to 23
Slice
3 = Bits 24 to 31
Slice
4 = Bits 32 to 39
Slice
5 = Bits 40 to 47
Slice
SIG_SCANTYPE ss ss Input scan type Rd 0 3 0
0 = Progressive
1 = Interleaved, Top field first
2 = Interleaved, Bottom field
first
3 = Segmented frame
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_HTOTAL_THEORIC sH sH Total number of pixels per line Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_HTOTAL_MAXI sM sM
Maximal number of pixels per
input line
Rd 0 65535
0 Unit = pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 54 55

Comentarios a estos manuales

Sin comentarios