Group Name Cmd
Resp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
SET_FREEZE Sf Sf Freeze of the input Rd/Wr 0 1 0 1 = Freeze
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
SET_MOTION_DETECT Sm Sm
0 : max correction; 15 : min
correction
Rd/Wr 0 15 15
0 = Input1
1 = Input2
2 = Input3
3 = Input4
8 = Input9
PRESET
ELEMENT
PE_INPUTNUM IN IN
Displayed input number or frame
or logo number
Rd/Wr 0 9 0
0 = No input
1 = Input1
2 = Input2
3 = Input3
4 = Input4
9 = Input9
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_SOURCENUM IS IS Source number Rd/Wr 0 64 0 Same Orc-50
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2
PE_AUDIO_AUX_MUTE
Aa
Aa
Auxiliary input mixing enable
Rd/Wr 0 1 0 1 = Enable.
0 = Current preset
1 = Next preset
2 = Previous
preset
3 = Memory
Preset 1
4 = Memory
Preset 2
5 = Memory
Preset 3
6 = Memory
Preset 4
2 = Background
Layer for output 1
8 = Audio Output 1
9 = Audio Output 2