Analog-way OPS300 Programmer's Guide Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 58
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
24
Group Name Cmd
Resp
Description
Read /
Write
Min
value
Max
value
Default
value
Values Index #1 Index #2
SET_HUE Su Su Input hue (NTSC only) Rd/Wr
0 255 128 128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_HTOTAL ST ST Input total pixel per line Rd/Wr
0 65535
0 Unit = pixels.
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_PHASE SS SS Input Phase Rd/Wr
0 31 16
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 57 58

Comentarios a estos manuales

Sin comentarios