49
Group Name CmdResp
Description
Read
/
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PSTATUS_REFRESH_INTERVAL Pi Pi
Time between 2 frames of an
animated logo
Rd/Wr
1 10000
56 Unit = 1ms
1 = Logo 1
2 = Logo 2
3 = Logo 3
4 = Logo 4
5 = Logo 5
6 = Logo 6
7 = Logo 7
9 = Frame 1
10 = Frame 2
11 = Frame 3
12 = Frame 4
13 = Frame 5
14 = Frame 6
15 = Frame 7
LAN
LANENABLE ne ne LAN enable
Rd/Wr
0 1 0
0 = Enable RS232 ( disable LAN )
1 = Enable LAN ( disable RS232 )
LANRESET nr nr LAN factory parameters reset
Rd/Wr
0 1 0
Auto reset
LANSTORE ns ns LAN parameters update
Rd/Wr
0 1 0
Auto reset
LANIP nw nw LAN devices addresses
Rd/Wr
0 255 192 IP : 0 to 255
0 = Device
1 = Remote
2 = Gateway
0 = IP address
high byte
1 = IP address
mid high byte
2 = IP address
mid low high byte
3 = IP address
low byte
LANPORT np np LAN port numbers
Rd/Wr
0 65535
10500
Local port : 10000 à 10999
Remote port : 0 à 65500
0 = Device
1 = Remote
2 = Gateway
LANNETMASK nk nk LAN netmask
Rd/Wr
0 24 8 Number of 0bits from the right
LANPROTOCOL nt nt LAN protocol
Rd/Wr
0 1 1
0 = UDP Protocol
1 = TCP protocol
2 = AMX Protocol
Vista de pagina 48