Group Name CmdResp
Description
Read /
Write
Min
Value
Max
value
Default
value
Values Index #1 Index #2
PE_CLOSING_TRANSITION cT cT Layer closing transition type Rd/Wr 0 4 2
0 = Cut
1 = CleanCut
2 = Fade
3 = Slide (associée à 1
trajectoire)
4 = Wipe (associée à 1
trajectoire)
0 = Current preset
1 = Next preset
2 = Previous preset
3 = Memory Preset 1
4 = Memory Preset 2
5 = Memory Preset 3
6 = Memory Preset 4
0 =
Background
Frame for
output 1
1 =
Background
Frame for
output 2 in
matrix mode
2 =
Background
Layer for
output 1
3 = Pip 1 Layer
for output1
Background
Layer for
output 2 in
matrix mode
6 = Logo 1
7 = Logo 2
8 = Audio
Output 1
9 = Audio
Output 2